Component Location
General Description

The normal operating temperature of the HO2S(Heated Oxygen Sensor) ranges from 350 to 850℃(662 to 1562℉). The HO2S heater greatly decreases the amount of time required for fuel control to become active. The PCM provides a pulse width modulated control circuit to adjust current through the heater.

When the HO2S is cold, the value of the resistance is low and the current in the circuit is high. Conversely, if the temperature in the resistor of the sensor rises, the current drops gradually.

DTC Description

DTC P0135 is a pending code. The root cause will be confirmed by P0030, P0606, P2243, P2251.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Evaluate O2 sensor heater performance.

1.

Related fuse blown or missing

2.

Heater control circuit open or short

3.

Power supply circuit open or short

4.

Poor connection or damaged harness

5.

Faulty HO2S

Enable

Conditions

Case1

•

Heater PWM > 1.56%

•

Sensor operative readiness (Tip temp.>640°C(1,184℉) or 18sec. heating time after Dew-point detection)

Case2

•

11 ≤ Battery voltage ≤ 16V

Threshold

Value

Case1

•

Front HO2S tip temp. : < 755°C(1,391℉) or > 900°C(1,652℉)

Case2

•

Error bit information from HW circuit

Diagnostic

Time

Case1

•

Temp. < 640°C(1,184℉) : 1sec.

•

640°C(1,184℉) < Temp. < 755°C(1,391℉) : 10sec.

•

900°C(1,652℉) < Temp. : 10sec.

Case2

•

5 seconds

MIL On Condition

•

2 Drive Cycles

Specification

HO2S Heater

Normal Parameter

18 ~ 20℃

Heater Resistance

2.4 ~ 2.9Ω

Diagnostic Circuit Diagram