Removal
1.

Remove the coupling assembly.

(Refer to Coupling Assembly - " Direct Electro Hydraulic Actuator Coupling")

2.

Remove the extension cable (A).

3.

Remove the pressure sensor (A) with 24mm socket.

note
●

Keep going horizontal state to prevent leaks during remove the pressure sensor.

Tightening torque:

7.8 ~ 9.8 N.m (0.8 ~ 1.0kgf.m, 5.8 ~ 7.2 lb-ft)