Removal
1.

Remove the coupling assembly.

(Refer to Coupling Assembly - " Direct Electro Hydraulic Actuator Coupling")

2.

Remove the extension cable (A).

3.

Remove the pressure sensor (A) with 24mm socket.

note

Keep going horizontal state to prevent leaks during remove the pressure sensor.

Tightening torque:

7.8 ~ 9.8 N.m (0.8 ~ 1.0kgf.m, 5.8 ~ 7.2 lb-ft)