Inspection
1.

Measure the pressure of high pressure line by measuring voltage output between terminal “1” and “2”.

2.

Inspect the voltage value whether it is sufficient to be regular value or not.

Voltage = 0.00878835 * Pressure + 0.5

3.

If the measured voltage value is not wihtin specification, replace the A/C pressure transducer.