Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the auto defogging connector.

3.

Verify that the auto defogging actuator operates to the open position when connecting 12V to terminal 3 and grounding terminal 4.

Verify that the auto defogging actuator operates to the close position when connected in reverse.

1. -

2. -

3. OPEN

4. CLOSE

5. Sensor (+ 5V)

6. Feedback signal

7. Sensor ground

4.

Connect the auto defogging actuator connector.

5.

Turn the ignition switch ON.

6.

Check the voltage between terminals 6 and 7.

Specification

Door position

Voltage (V)

Error detecting

Defog OFF (CLOSE)

0.45±0.15

Low voltage : 0.1V or less

High voltage : 4.9V or less

Defog ON (OPEN)

4.55±0.15

It will feedback the current position of the actuator to controls.

7.

If the measured voltage is not within specification, substitute with a known-good auto defogging actuator and check for proper operation.

8.

Replace the auto defogging actuator if it is proved that there is a problem with it.