Self Diagnosis
1.

Self-diagnosis process

2.

How to read self-diagnostic code

After the display panel blinks three times every 0.5 second, the corresponding fault code blinks on the setup temperature display panel every 0.5 second and will show two figures. Codes are displayed in numerical format

Fault code

Display

Fail Description

00

Normal

11

In-car temperature sensor short (Low)

12

In-car temperature sensor open (High)

13

Ambient temperature sensor short (Low)

14

Ambient temperature sensor open (High)

17

Evaporator sensor short (Low)

18

Evaporator sensor open (High)

19

Air mix potentiometer open (Low) - Driver

Air mix potentiometer short (High) - Driver

21

Direction potentiometer open (Low) - Driver

Direction potentiometer short (High) - Driver

20

Air mix motor - Driver

22

Direction control motor - Driver

25

Intake potentiometer open (Low)

Intake potentiometer short (High)

26

Intake motor

32

Air mix potentiometer open (Low) - Passanger

Air mix potentiometer short (High) - Passanger

33

Air mix motor - Passanger

44

Cluster Ionizer fault

31

Auto defogging sensor signal and Glass sensor input fault

40

DEF Direction potentiometer open (Low)

DEF Direction potentiometer short (High)

41

DEF Direction control motor

46

APT sensor Fault (CAN signal)

47

Engine RPM Fault (CAN signal)

48

Vehicle Speed Sensor Fault (CAN Signal)

49

Engine Coolant Temp Sensor Fault (CAN Signal)

3.

Fault code display

(1)

Continuance operation : None or one DTC code.

(2)

Continuance operation : Two or more DTC code.

(3)

STEP operation

A.

Nomal or one fault code is same as a continuance operation.

B.

Two or more DTC code.

4.

If fault codes are displayed while checking, inspect for malfunction causes by referring to the fault code table.

5.

Fail Safe

No

Sensor

Fail condition

Fail safe function

1

In-car sensor

< 0.1V or > 4.9V

23℃ (73.4℉)

2

Ambient temperature sensor

< 0.1V or > 4.9V

20℃ (68℉)

3

Evaporator temperature sensor

< 0.1V or > 4.9V

 -2℃ (28.4℉)

4

Temperature control actuator feedback - Driver

< 0.1V or > 4.9V

Setting temperature is 24.5℃ (76.1℉) or below

Setting temperature is 25.0℃ (77℉) or above: Max hot

5

Mode control actuator feedback - Driver

< 0.1V or > 4.9V

Vent: Vent

Others: Defog

6

Intake actuator feedback

< 0.1V or > 4.9V

Recirculation: Recirculation

Others: Fresh

7

Temperature control actuator feedback - Passenger

< 0.1V or > 4.9V

Setting temperature is 24.5℃ (76.1℉) or below

Setting temperature is 25.0℃ (77℉) or above: Max hot

8

Auto defogging sensor (Relative humidity)

Communication fail

Relative humidity: 60%,

Surrounding temperature : 23℃ (73.4℉) 

9

Auto defogging actuator feedback

< 0.1V or > 4.9V

Close: Close

Others: Open 