Turn the ignition switch off.
Disconnect the LP-EGR solenoid valve connector.
Measure the resistance between 1 and 2 terminal of the solenoid valve.
Check that the resistance is within the specification.
▷ Specification
Item | Specification |
Coil Resistance (Ω) | 14.7 ~ 15.1 [20℃(68℉)] |
Connect the GDS to the data link connector.
Perform the fully open and the fully closing operation of the LP-EGR valve by using the actuation test.
Check that the voltage is within the specification.
▷ Specification
Item | Specification | |
Component (Reference voltage : 5V) | On vehicle (Reference voltage : 3.3V) | |
Output voltage (V) [At the fully open position] | 4.1 ~ 4.7 | 2.7 ~ 3.1 |
Output voltage (V) [At the fully closed position] | 0.4 ~ 0.8 | 0.27 ~ 0.53 |