Turn the ignition switch off.
Disconnect the Variable swirl actuator connector.
Check if there is the foreign material inside the Variable swirl actuator.
Measure the resistance between 1 and 3 terminal of the Variable swirl actuator.
Check that the resistance is within the specification.
▷ Specification
Item | Specification |
Coil Resistance (Ω) | 3.4 ~ 4.4 [20℃(68℉)] |
Connect the GDS to the data link connector.
Perform the fully open and the fully closing operation of the Variable swirl actuator by using the actuation test.
Check that the voltage is within the specification.
▷ Specification
Item | Specification |
Output voltage (V) | 0.17 ~ 4.83 |