Inspection
[Solenoid valve]
1.

Turn the ignition switch off.

2.

Disconnect the LP-EGR solenoid valve connector.

3.

Measure the resistance between 1 and 2 terminal of the solenoid valve.

4.

Check that the resistance is within the specification.

▷ Specification

Item

Specification

Coil Resistance (Ω)

14.7 ~ 15.1 [20℃(68℉)]

[Feedback position sensor]
1.

Connect the GDS to the data link connector.

2.

Perform the fully open and the fully closing operation of the LP-EGR valve by using the actuation test.

3.

Check that the voltage is within the specification.

▷ Specification

Item

Specification

Component

(Reference

voltage : 5V)

On vehicle

(Reference

voltage : 3.3V)

Output voltage (V)

[At the fully open

position]

4.1 ~ 4.7

2.7 ~ 3.1

Output voltage (V)

[At the fully closed

position]

0.4 ~ 0.8

0.27 ~ 0.53

Яндекс.Метрика