Removal and Installation
caution

When the oil level sensor signal fault occurs, refer to the DTC guide.

1.

Drain the engine oil.

2.

Remove the oil level sensor (A) from the oil pan after disconnecting the connector.

Tightening torque :

8.8 ~ 9.8 N.m (0.9 ~ 1.0 kgf.m, 6.5 ~ 7.2 lb-ft)

3.

Install in the reverse order of removal. , with a new gasket.