Inspection
1.

Immerse the thermostat in water and gradually heat the water.

2.

Check the valve opening temperature.

Valve opening temperature: 82°C (177°F)

Full opening temperature: 95°C (205˚F)

If the valve opening temperature is not as specified, replace the thermostat.

3.

Check the valve lift.

Valve lift : 8 mm (0.3 in) or more at 95°C (205˚F)

If the valve lift is not as specified, replace the thermostat.