IG "OFF". Disconnect OCV and PCM connector.
Measure resistance between power and signal terminals of OCV. (Component Side)
Specification : 9.4 ~10.4 [20℃(68℉)]
Is the measured resistance within specification?
![]() | ▶ Go to "OCV Actuation Test" as follows. |
![]() | ▶ Substitute with a known - good OCV and check for proper operation. If the problem is corrected, replace OCV and go to "Verification of Vehicle Repair" procedure. |
Connect GDS and IG "ON".
Select "OIL CONTROL VALVE" on the Actuation Test.
Activate "OIL CONTROL VALVE" by pressing "START" button.
(Should hear a faint click from Oil Control solenoid Valve)
Repeat this procedure 4 or 5 times to ensure oil control solenoid valve reliability.
Does OCV generate click sound during actuation test?
![]() | ▶ Substitute with a known - good PCM and check for proper operation. If the problem is corrected, replace PCM and go to "Verification of Vehicle Repair" procedure. |
![]() | ▶ Substitute with a known - good OCV and check for proper operation. If the problem is corrected, replace OCV and go to "Verification of Vehicle Repair" procedure. |