Installation
1.

Before installation, wipe the surface with a clean cloth.

2.

Check the O-rings (A) of the new hydraulic motor (actuators).

note

You have to prevent any dust from entering inside hydraulic motors (actuators) and housing.

3.

Tighten the bolts after install the hydraulic motor (actuators).

note

When installing, motor connector has to toward in the direction of outside of the Coupling.

Tightening torque:

8.8 ~ 10.8 N.m (0.9 ~ 1.1 kgf.m, 6.5 ~ 8.0 lb-ft)

note

When installing, oil can be reflux by the pressure in air breather hole.

Change direction in the direction of the arrow and lay on the floor as shown in the illustration.

※ The reflux oil will flow to the bottom.

You have to prevent additional backflow in according to order as shown in the illustration.

4.

Wipe the flowed oil to around the surface with a clean cloth.

5.

Install the coupling assembly.

(Refer to Coupling Assembly - " Direct Electro Hydraulic Actuator Coupling")