Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the intake actuator connector.

3.

Verify that the intake actuator operates to the fresh position when connecting 12V to terminal 3 and grounding terminal 4.

Verify that the intake actuator operates to the recirculation position when connected in reverse.

1. -

2. -

3. Recirculated air

4. Fresh air

5. Sensor (+ 5V)

6. Feedback signal

7. Sensor ground

4.

Connect the intake actuator connector.

5.

Turn the ignition switch ON.

6.

Check the voltage between terminal 6 and 7.

Specification

Door position

Voltage (V)

Error detecting

Fresh air

0.5

Low voltage : 0.1V or less

High voltage : 4.9V or less

Recirculated air

4.5

It will feedback the current position of the actuator to controls.

7.

If the intake actuator does not operate well, substitute with a known-good intake actuator and check for proper operation.

8.

Replace the intake actuator if it is proved that there is a problem with it.

Яндекс.Метрика