Turn the ignition switch OFF.
Disconnect the mode control actuator connector.
Verify that the mode control actuator operates to the defog mode when connecting 12V to terminal 3 and grounding terminal 4.
Verify that the mode control actuator operates to the vent mode when connected in reverse.
1. - 2. - 3. Defrost mode 4. Vent mode | 5. Sensor ground 6. Feedback signal 7. Sensor (+ 5V) |
Connect the mode control actuator connector.
Turn the ignition switch ON.
Check the voltage between terminal 5 and 6.
Specification
Door position | Voltage (V) | Error detecting |
Vent | 0.45±0.15 | Low voltage : 0.1V or less High voltage : 4.9V or less |
Defrost | 4.55±0.15 |
It will feedback the current position of the actuator to controls.
If the measured voltage is not within specification, substitute with a known-good mode control actuator and check for proper operation.
Replace the mode control actuator if it is proved that there is a problem with it.
Disconnect the negative (-) battery terminal.
Using a screwdriver or remover, remove the driver's side crash pad side cover.
After loosening the mounting screws, remove the crash pad lower panel (A).
Push the lock pin (B), disconnect the diagnosis connector (C).
After loosening the mounting bolts, then remove the reinforce panel (A).
Remove the driver's side shower duct after loosening the screw.
Disconnect the connector and then remove the mode control actuator (A) after loosening the mounting screws.
Install in the reverse order of removal.