Component Inspection
■ Shift control solenoid valve(SS-B) Inspection
1.

Ignition off & Engine Off.

2.

Disconnect "ATM solenoid valve connector.

3.

Measure a resistance between "Shfit control solenoid valve(SS-B) " terminal and power at ATM solenoid valve connector.

Specification : 10 ~ 11 Ω(20℃)

4.

Is measured resistance within specification?

▶ Substitute with a known-good TCM and check for proper operation.If the problem is corrected, replace TCM and then go to "Verification of Vehicle Repair" procedure.

▶ Substitute with a known-good Shift control solenoid valve(SS-B) and then go to "Verification of Vehicle Repair" procedure.