DTC Description

PCM/ECM sets DTC P06A4 if the PCM/ECM detects reference voltage of APT is lower than threshold value.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

Case 1

DTC

Strategy

•

Short to ground

1.

Short to ground in power circuit

2.

Poor connection or damaged harness

3.

Faulty APT

Enable

Conditions

•

IG "ON"

Threshold

Value

•

Short to ground

•

APT power supply voltage < 0.7 V

Case 2

DTC

Strategy

•

Electrical check

Enable

Conditions

•

IG ON

Threshold

Value

•

Sensor or harness problem

•

0.7 V ≤ APT power supply voltage < 4.5 V

Diagnostic Time

•

0.1 sec.

Mil On Condition

•

1 driving cycle

( ※ APT : Air-Con Pressure Transducer )