DTC Description

If the HO2S signal voltage is fixed at lean status, then feedback control is no longer possible, the PCM/ECM sets DTC P2195.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Characteristic line strong shift

1.

Poor connection or damaged harness

2.

Front HO2S

Enable Conditions

•

Wide range sensor pump current valid

•

Downstream O2 sensor operative readiness

•

Active test not activated

•

ngine speed > 600rpm

•

Mass air flow < 83g/sec(300kg/h)

•

572 F(300℃) < Exhaust gas temperature < 1472 F (800℃)

Threshold Value

•

Plausibility between upstream and downstream

•

Upstream lean & downstream rich & lambda controller limit or upstream rich & downstrean lean & lambda controller limit

Diagnostic Time

•

Less than 1300 sec.

Mil On Condition

•

2 Driving Cycles