DTC Description

In case the sensor output is 0.4~0.52 V during 600sec or the internal resistance is over 40 ㏀ under enable conditions, ECM/PCM sets DTC P0136. ( This DTC might be caused by the malfunction of Heater circuit, so, check the heater circuit first. )

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC

Strategy

Case 1

Feedback check

1.

Poor connection

2.

Open or short in signal circuit

3.

Downstream O2S

Case 2

Internal resistance check

Case 3

O2S signal monitoring

Enable

Conditions

Case 1

[Duration of 0.4 < Down O2S < 0.5V] > 3 sec

Load pulse : End of 3rd pulse

Battery voltage > 10.7V

Case 2

Battery voltage > 10.7V

Exhaust Gas temperature around downstream O2S > 600℃

Case 3

Battery voltage > 10.7V

Time after heat quantity > 10 sec

Threshold

Value

Case 1

Average of loaded voltage > 2.8V

Case 2

Internal resistance > 40kΩ

Case 3

[Counter of ∆ downstream O2S voltage > 2V during 0.04 sec after heater on->off] > 4 times

Diagnosis Time

-

MIL ON Condition

2 trips

※ S2 : upstream oxygen sensor / S2 : downstream oxygen sensor