If measured temperature is lower than the minimum threshold value during 100sec, ECM sets DTC P0113.
(In this case, the input signal voltage is the maximum threshold vaue.)
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Signal check, high | 1. Poor connection 2. Open or short to power in signal circuit 3. Open in ground circuit 4. IATS |
Enable Conditions |
•
Elapsed time after start is higher than 2 sec. | |
Threshold Value |
•
Measured temperature is lower than -45 ℃ | |
Diagnostic Time |
•
2 sec. | |
MIL ON Condition |
•
2 Drive Cycle |