If the sensor output is over 1.08 V under enable conditions, ECM sets P0132.
(This DTC might be caused by the malfunction of Heater circuit, so, check the heater circuit first.)
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Rationality check | 1. Poor connection 2. Short to Power in signal circuit 3. S1 |
General Enable Conditions |
•
Dew point end detected
•
Fuel feed back control active
•
Battery voltage is higher than 11V
•
Exhaust Gas temperature is between 280℃ and 800℃.
•
No injector error
•
No upstream O2 sensor heater error | |
Threshold Value |
•
S1 sensor voltage is higher than 1.08V | |
Diagnostic Time |
•
5 sec. | |
MIL ON Condition |
•
2 driving cycle |