Inspection
Front Seat
1.

Check for continuity and measure the resistance between terminals.

No.

Description

No.

Description

1

Heater (+)

3

NTC (-)

2

NTC (+)

4

Heater (-)

Standard value (Fabric / Leather)

Cushion : 1.14 Ω ± 10%

Back: 1.04 Ω ± 10%

Set : 2.18 Ω ± 10%

2.

Operate the seat heater after connecting the connector, and then check the NTC by measuring the temperature of seat surface.

1st

2nd

3rd

Cushion

(±2°C)

36°C

39°C

42°C

Back

(±2°C)

40°C

45°C

50°C

Second Seat
1.

Check fo continuity and measure the resistance between terminals.

No.

Description

No.

Description

1

Battery (+)

5

LED Low

2

IGN 1

6

Ground

3

LED High

7

Heater switch

4

IGN 2

8

-

2.

Operate the seat heater after connecting the connector, and then check the thermostat by measuring the temperature of seat surface.

1st

2nd

Cushion

(±2°C)

36°C

39°C