Place the shift lever into the "N" position.
Remove the air cleaner assembly.
(Refer to Engine Mechanical System - "Air cleaner")
Remove the battery and the battery tray.
(Refer to Engine Electrical System - "Battery")
Disconnect the inhibitor switch connector (A).
Remove the shift cable mounting nut (A).
Remove the manual control lever (B) and the washer after removing a nut (A).
Remove the inhibitor switch (A) after removing the bolts (2ea).