Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Recover the refrigerant with a recovery/charging station.

3.

Disconnect the A/C pressure transducer connector (A).

4.

Remove the A/C pressure transducer (A).

Tightening torque:

10.0 ~ 12.0 N.m (1.02~ 1.22 kgf.m, 7.4~8.8 lb-ft)

caution

Be careful not to bend the liquid & suction pipe.

5.

Install in the reverse order of removal.

note

When installing, replace it with a new O-ring (A).