Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the mode control actuator connector.

3.

Verify that the mode control actuator operates to the defog mode when connecting 12V to the terminal 3 and grounding terminal 7.

Verify that the mode control actuator operates to the vent mode when connecting in the reverse.

1. -

2. -

3. Defrost mode

4. Sensor ground

5. Feedback signal

6. Sensor (+ 5V)

7. Vent mode

4.

Connect the mode control actuator connector.

5.

Turn the ignition switch ON.

6.

Check the voltage between terminal 6 and 5.

Specification

Door position

Voltage (V)

Error detecting

Vent

0.3 ± 0.15

Low voltage : 0.1V or less

Defrost

4.7 ± 0.15

High voltage : 4.9V or more

It will feedback the current position of the actuator to the controls.

7.

If the measured voltage is not within specification, substitute with a known-good mode control actuator and check for proper operation.

8.

Replace the mode control actuator if it is proved that there is a problem with it.