Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the auto defogging connector.

3.

Verify that the auto defogging actuator operates to the open position when connecting 12V to the terminal 3 and grounding terminal 7.

Verify that the auto defogging actuator operates to the close position when connecting in the reverse.

1. -

2. -

3. Open

4. Sensor (+ 5V)

5. Feedback signal

6. Sensor ground

7. Close

4.

Connect the auto defogging actuator connector.

5.

Turn the ignition switch ON.

6.

Check the voltage between terminals 6 and 5.

Specification

Door position

Voltage (V)

Error detecting

Defog OFF (Close)

0.3 ± 0.15

Low voltage : 0.1V or less

Defog ON (Open)

4.7 ± 0.15

High voltage : 4.9V or more

It will feedback the current position of the actuator to the controls.

7.

If the measured voltage is not within specification, substitute with a known-good auto defogging actuator and check for proper operation.

8.

Replace the auto defogging actuator if it is proved that there is a problem with it.