Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the intake actuator connector.

3.

Verify that the intake actuator operates to the recirculation position when connecting 12V to terminal 3 and grounding terminal 7.

1. -

2. -

3. Fresh

4. Sensor (+ 5V)

5. Feedback

6. Sensor Ground

7. Recirculation

4.

Connect the intake actuator connector.

5.

Turn the ignition switch ON.

6.

Check the voltage between terminal 6 and 7.

Specification

Door position

Voltage (V) 

Error detecting

Fresh

0.3 ± 0.15

Low voltage : 0.1V or less

Recirculation

4.7 ± 0.15

High voltage : 4.9V or more

7.

If the intake actuator dones not operate well, substitute with a known-good intake actuator and check for proper operation.

8.

Replace the intake actuator if it is proved that there is a problem with it.