Inspection
Component Inspection
1.

Remove the ignition lock switch.

2.

Push the ignition lock switch in the direction of the arrow to make sure that continuity between terminals. (refer to the table below)

Standard value :

Full stroke (A): 12.0 ± 0.3mm (0.4724 ± 0.0118 in.)

ON-OFF point (B): 2.0 mm (0.0787 in.)

caution

Condition

Clutch Pedal pressed

Clutch Pedal Released

Switch Operation

ON (below 1.0Ω )

OFF ( Infinite Ω )