Turn the ignition switch OFF.
Disconnect the IATS connector.
Measure resistance between the IATS terminals 3 and 4.
Check that the resistance is within the specification.
Specification: Refer to “Specification”
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
Disconnect the manifold absolute pressure sensor connector (A).
Remove the installation bolt (B), and then remove the sensor from the surge tank.
Install the component with the specified torques.
Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.
Insert the sensor in the installation hole and be careful not to damage when installation.
Install in the reverse order of removal.
Intake air temperature sensor installation bolt:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)