Removal And Installaion
Cooling fan assembly
1.

Disconnect the battery "-" terminal.

2.

Remove the air cleaner assembly.

(Refer to Intake And Exhaust System-"Air Cleaner")

3.

Disconnect the over flow hose (A).

4.

Disconnect the cooling fan coonector (A).

5.

Remove the filler neck bolts (A).

Tightening torque :

6.9 ~ 10.8 N.m (0.7 ~ 1.1 kgf.m, 5.1 ~ 8.0 lb-ft)

6.

Remove the cooling fan assembly (A).

Tightening torque :

4.9 ~ 7.8 N.m (0.5 ~ 0.8 kgf.m, 3.6 ~ 5.8 lb-ft)

7.

Install in the reverse order of removal.

Resister
1.

Disconnect the battery "-" terminal.

2.

Disconnect the wire harness connector (A) and the fan motor connector (B).

3.

Remove the resister (A) from the cooling fan shroud.

Tightening toraue :

1.8 ~ 2.5 N.m (0.18 ~ 0.25 kgf.m, 1.3 ~ 1.8 lb-ft)

4.

Install in the reverse order of removal.