Monitor GDS Data
1.

Connect GDS to Data Link Connector(DLC).

2.

Start engine and turn the headight and the heatwire on.

3.

Monitor the BATTERY VOLTAGE parameter on the "Current Data" With GDS.

4.

Maintaining ENG. RPM at 2,500RPM(idle) over 2 minutes.

Specification : more than 10 [V]

5.

Is parameter within specifications?

▶ Fault is intermittent and caused either by poor contact in connectors or wiring harness, or it has been repaired and EPS CM memory is not cleared yet. Thoroughly check all connectors (and connections) for looseness, bending, corrosion, contamination, deterioration, and/or damage.

▶ Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.

▶ Go to Next procedure.

▶ Go to "W/Harness Inspection" procedure.