If there is Open in PCSV circuit, ECM sets DTC P0444.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Circuit continuity check, open | 1. Poor connection 2. Open or Short to ground in power circuit 3. Open in control circuit 4. PCSV |
Enable Conditions |
•
Battery voltage is between 10.7V and 16V | |
Threshold Value |
•
Disconnected | |
Diagnostic Time |
•
Continuous | |
MIL ON Condition |
•