DTC Description

PCM/ECM sets DTC P0031 if the PCM/ECM detects that the front HO2S heater control circuit is short to ground.

DTC Detecting Condition - BINARY

Item

Detecting Condition

Possible Cause

DTC Strategy

Electrical Check

1.

Related fuse blown or missing

2.

Open or short to ground in power supply or control harness

3.

Poor connection or damaged harness

4.

Faulty HO2S

Enable Conditions

No relevant failure

10V< Battery voltage <16V

3.5%< O2 sensor heater control duty <96.5%

Threshold Value

HO2S Heater Output < Lower Threshold

Diagnostic Time

10 sec.

Mil On Condition

2 Driving Cycles

DTC Detecting Condition - LINEAR

Item

Detecting Condition

Possible Cause

DTC Strategy

Electrical Check

1.

Related fuse blown or missing

2.

Open or short to ground in power circuit

3.

Short to ground in control circuit

4.

Poor connection or damaged harness

5.

Faulty HO2S

Enable Conditions

10V < Battery voltage < 16V

1.5% < Heater power < 98.5%

Exhaust gas Temp. > 300°C (572℉)

Threshold Value

Short to ground

Diagnostic Time

1sec.

Mil On Condition

2 Driving Cycles