DTC Description - BINARY

PCM/ECM sets DTC P0131 if the HO2S(B1S1) voltage remains excessively low for a predetermined time.

DTC Description - LINEAR

The control unit of the linear oxygen sensor built inside the PCM/ECM monitors short circuit error on all front Heated Oxygen Sensor (HO2S) control lines (VRC, VIP, VG, VN) and PCM/ECM sets P0131 with short circuit to ground.If same code is set again in the next driving cycle, MIL is illuminated.

DTC Detecting Condition - BINARY

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage range check

1.

Short to ground in signal harness

2.

Poor connection or damaged harness

3.

Faulty Heated O2 Sensor(HO2S)

Enable Conditions

Lambda close loop activated

Lambda controller on max. limit during 10 sec.

Canister purge valve closed

No relevant failure

10V< Battery voltage <16V

Threshold Value

HO2S(B1S1) < 0.02V

Diagnostic Time

60 sec.

Mil On Condition

2 Driving Cycles

DTC Detecting Condition - LINEAR

Item

Detecting Condition

Possible Cause

DTC Strategy

Electrical check

1.

Short to ground in signal harness

2.

Poor connection or damaged harness

3.

Faulty Heated O2 Sensor(HO2S)

Enable Conditions

10V < Battery voltage < 16V

Ignition key On

Threshold Value

Error bit information from HW circuit

Diagnostic Time

0.5 Seconds

Mil On Condition

2 Driving Cycles