DTC Description

If the input signal voltage of IATS is higher than the maximum threshold value, ECM/PCM sets DTC P0113

.(In this case, the input signal voltage is the maximum threshold value.)

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Signal check, high

1.

Poor connection

2.

Open or short to power in signal circuit

3.

Open in ground circuit

4.

IATS

Enable Conditions

ECT at Start ≥ - 30℃

After ECT > 70℃ & Air mass < 20 kg/h & Vehicle speed < 6.2mph condition for 10 sec.

Threshold Value

Input signal voltage of IATS > 4.93V(< -34.8 ℃)

Diagnosis Time

-

Mil On Condition

2 trips