DTC Description

If ECM/PCM detects short to ground in signal circuit, ECM/PCM sets DTC P0137.

( This DTC might be caused by the malfunction of Heater circuit, so, check the heater circuit first. )

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC

Strategy

Case 1

Signal check, low by Load pulse

1.

Poor connection

2.

Short to ground in signal circuit

3.

Downstream O2S

Case 2

Signal check, low

Enable

Conditions

Case 1

[Duration of down O2S < 0.06V] > 3 sec.

Load pulse : End of 3rd pulse

Case 2

Short term FT < 1.25 (upper limit)

Battery voltage > 10.7V

Heat quantity from exhaust gas around downstream O2S > 1~312kJ

Threshold

Value

Case 1

Average of voltage difference between loaded and unloaded voltage < 0.015V

Case 2

Downstream O2S voltage < 0.06V

Diagnosis Time

-

MIL On Condition

2 trips

※ S1 : upstream oxygen sensor / S2 : downstream oxygen sensor