DTC Description

ECM/PCM shows P0191 when the average value from fuel rail pressure sensor is out of range of threshold value. This code is for abnormal sensor

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC

Strategy

Case 1

High pressure sensor output check

1.

Poor connection

2.

FPS

Case 2

Rationality check negative offset

Case 3

Rationality check positive offset

Enable

Conditions

Case 1

Sensor Output Volatage > 4.9V

Sensor Output Volatage < 0.20V

Case 2

Multiplicative Long Term FT < 0.8%

Adaptive Long Term FT < -6.0%

IG ON

Case 3

Multiplicative Long Term FT > 1.2

Adaptive Long Term FT > 6.0%

IG ON

Threshold

Value

Case 1

Sensor Output Voltage Jump time < 0.06 sec.

Case 2

Relative pressure < 0.13MPa

Case 3

Relative pressure > 1.3MPa

Diagnosis Time

-

MIL ON Condition

2 trips

Яндекс.Метрика