DTC Description

If measured temperature is lower than the minimum threshold value during 300sec, ECM sets DTC P0113.

(In this case, the input signal voltage is the maximum threshold vaue.)

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Signal check, high

1.

Poor connection

2.

Open or short to power in signal circuit

3.

Open in ground circuit

4.

IATS

Enable Conditions

Elapsed time after start is higher than 2 sec.

Threshold Value

Measured temperature is lower than -45 ℃

Diagnostic Time

300 sec.

MIL ON Condition

3 Drive Cycle