DTC Description

If ECM detects that the output signal satisfies the threshold values under enable conditions, ECM sets DTC P0130.

(This DTC might be caused by the malfunction of Heater circuit, so, check the heater circuit first.)

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Rationality check

1.

Poor connection

2.

Open or short power/ground in signal circuit

3.

S1

General

Enable

Conditions

Dew point end detected

Fuel feed back control active

Battery voltage is higher than 11V

Exhaust Gas temperature is between 280℃ and 800℃

No injector error

No upstream O2 sensor heater error

Case1

Enable

Conditions

S2 sensor voltage is higher than 0.5V

ThresholdValue

S1 sensor voltage is between 0.06V and 0.4V

DiagnosticTime

25 sec.

Case2

Enable

Conditions

S2 sensor voltage is lower than0.1V

ThresholdValue

S1 sensor voltage is between 0.06V and 0.4V

DiagnosticTime

10 sec.

Case3

Enable

Conditions

-

ThresholdValue

The number of that the absolute value of ∆usvk is greater than 2V during 0.04 sec after turning on and off a heater is more than or equal to 5 times

MIL ON Condition

3 driving cycle

※ ∆usvk : Sum of the signal voltage change value (S1)