ECM assumes that O2 sensor heater coil is abnormal and shows P0135 when the corrected resistance value of upstream O2 sensor heater is higher than the specification.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Signal check | 1. Poor connection 2. Open or Short to ground in power circuit 3. Open in control circuit 4. S1 |
Enable Conditions |
•
Exhaust Gas temperature is higher than 450°C
•
Heating period is higher than 50 sec.
•
Battery voltage is between 10.7V and 16.1V | |
Threshold Value |
•
When Internal resistance is greater than threshold value (Calculated by exhaust gas temp.or heating power) | |
Diagnostic Time |
•
60 sec. | |
MIL ON Condition |
•