Terminal and Connector Inspection
1.

Many malfunctions in the electrical system are caused by poor harness and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

3.

Have any problems been found?

▶ Repair as necessary and go to "Verification of vehicle Repair" procedure.

▶ Go to "Signal Cirtuit Inaspection" procedure.

Signal Cirtuit Inaspection
1.

IG "OFF" & Disconnect ECTS connector.

2.

IG "ON".

3.

Measure voltage between signal terminal of ECTS harness connector and chassis ground.

Specification : Approx. 5V

4.

Is the measured voltage within specification?

▶ Go to "Ground Circuit Inspection" procedure.

▶ Repair or replace as necessary and then, go to "Verification of Vehicle Repair" procedue.

Ground Circuit Inspection
1.

IG "OFF" & Disconnect ECTS connector.

2.

IG "ON".

3.

Measure the voltage between signal terminal of ECTS harness connector and chassis ground.(A)

4.

Measure the voltage between signal and ground terminal of ECTS harness connector and chassis ground.(B)

Specification : "A" - "B" = Below 200mV

5.

Is the measured voltage within specification?

▶ Go to "Component Inspection" procedure.

▶ Repair or replace as necessary and then, go to "Verification of Vehicle Repair" procedue.