DTC Description

If the sensor output is below 0.06 V and the average of voltage difference between loaded and unloaded voltage is below 0.015 V under enable conditions, the ECM sets DTC P0137.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

Case 1

DTC

Strategy

Signal check, low by Load pulse

1.

Poor connection

2.

Short to ground in signal circuit

3.

S2

Enable

Conditions

Duration of down O2S < 0.06V for more than 3 sec.

Load pulse : End of 3rd pulse

Threshold

Value

Average of voltage difference between loaded and unloaded voltage < 0.015 V

Diagnostic

Time

3 sec.

Case 2

DTC

Strategy

Signal check, low

Enable

Conditions

Short term FT < 1.25 (upper limit)

B+ > 10.7 V

Heat quantity from exhaust gas

Around downstream O2S > 1~312 kJ

Threshold

Value

Downstream O2S voltage < 0.06 V

Diagnostic

Time

40 sec.

MIL ON Condition

2 driving cycles

※ S1 : upstream oxygen sensor / S2 : downstream oxygen sensor