Component Inspection
■ Perform High Pressure Fuel Pump
1.

Connect GDS to Data Link Connector(DLC).

2.

IG KEY "ON" & ENG "OFF".

3.

Perform "Actuation Test" for High Pressure Fuel Pump.

■ Inspection High Pressure Fuel Pump
4.

IG Key "OFF".

5.

Disconnect High Pressure Fuel Pump connector.

6.

Measure resistance between power and control terminal of the High Pressure Fuel Pump. (Component Side)

Specification : Approx. 1Ω±5% at 20°C(68 °F)

■ Confirm Part Inspection
7.

Does the High Pressure Fuel Pump operate properly? (Check variation)

▶ Go to "Verification of Vehicle Repair" procedure.

▶ Substitute with a known-good FPR and check for proper operation. If the problem is corrected, replace FPR and then go to "Verification of Vehicle Repair" procedure.