Terminal and Connector Inspection
1.

Many malfunctions in the electrical system are caused by poor harness(es) and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

3.

Has a problem been found?

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure

▶ Go to next step as below

Power Circuit Inspection
1.

IG "OFF".

2.

Disconnect EMS Box and Key "ON".

3.

Measure the voltage between power supply terminals of main relay harness connector and chassis ground.

Specification : B+

4.

Is the measured voltage within specification ?

▶ Go to "System Inspection" procedure.

▶ Check the fuse between battery and main relay.

▶ Repair open or short to ground in power harness and go to "Verification of Vehicle Repair" procedure .