Fig.1) Engine Idle after Warm Up
COM → Duty(+) Approx. 34%
Duty(-) Approx. 66%
FR → Duty(+) Approx. 58%
Duty(-) Approx. 42%
Fig.2) Electrical Load(Engine Idle after Warm Up)
COM → Duty(+) Approx. 34%
Duty(-) Approx. 66%
FR → Duty(+) Approx. 96%
Duty(-) Approx. 4%
Duty(+) from FR terminal is increased if electrical loads are ON(Head Lamp and Defrost are ON) ECM controls generation of alternator with duty from FR terminal when electrical Loads turn on.