Removal and Installation
1.

Disconnect the battery negative (-) terminal.

2.

Remove the air duct and RCV hose.

(Refer to Intake and Exhaust System - "Air Cleaner")

3.

Disconnect the over flow hose (A) from radiator.

4.

Disconnect the fan controller connectors (A).

5.

Remove the fan controller assembly (B).

Tightening torque :

4.9 ~ 8.3 N.m (0.5 ~ 0.85 kgf.m, 3.6 ~ 6.1 lb-ft)

6.

Disconnect the radiator upper hose (A).

7.

Remove the filler neck assembly bolts (A).

8.

Remove the MAPS.

(Refer to Engine Control / Fuel System - "Manifold Absolute Pressure Sensor(MAPS)")

9.

Remove the cooling fan assembly.

Tightening torque :

4.9 ~ 7.9 N.m (0.5 ~ 0.8 kgf.m, 3.6 ~ 5.8 lb-ft)

10.

Install in the reverse order of removal.