Inspection
1.

Disconnect the negative (-) battery terminal.

2.

Remove the roof trim assembly.

(Refer to Body - "Roof Trim Assembly")

3.

Disconnect the sunroof motor (A) connector.

4.

Ground the terminals as below table, and check that the sunroof unit operates.

note
-

When inspecting the sunroof motor operation, sunroof motor and roller blind motor always should be connected.

5.

Make these input tests at the connector. If any test indicates a problem, find and correct the cause, then recheck the system. If all the input tests prove OK, the sunroof motor must be faulty; replace it.

Terminal

Test

condition

Test: Desired result

3

IG2 ON

Check for voltage to ground:

There should be battery voltage.

1

Under all

conditions

Check for continuity to ground:

There should be continuity.

6

Under all

conditions

Check for voltage to ground:

There should be battery voltage.