Replacement
1.

Remove the condenser, and then remove the bottom cap (B) with a L wrench (A) from the condenser.

Tightening torque :

9.8~14.7N.m (1.0~1.5kgf.m, 7.2~10.8lb-ft)

2.

Remove the receiver-drier (A) from condenser using a long nose plier. Check for crumbled receiver-drier and clogged bottom cap filter.

3.

Apply air conditioning compressor oil along the O-rings and threads of the new bottom cap.

4.

Insert a new receiver-drier into the receiver drier tank. The receiver-drier must be sealed in vacuum before it is exposed to air for use.

5.

Install the new bottom cap to the condenser.

note
●

Always replace the receiver-drier and bottom cap at the same time.

●

Replace the O-rings with new ones at each fitting, and apply a thin coat of refrigerant oil before installing them. Be sure to use the right O-rings for R-134a to avoid leakage.

●

Be careful not to damage the radiator and condenser fins when installing the condenser.

●

Be sure to install the lower mount cushions of condenser securely into the holes.

●

Charge the system, and test its performance.