Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect ambient temperature sensor.

3.

Check the resistance of the ambient temperature sensor between terminals 1 and 2 whether it changes by changing the ambient temperature.

Specification

Ambient temperature [℃(℉)]

Resistance between terminals 1and 2 (㏀±3%)

-30(-22)

480.41

-20(-4)

271.21

-10(14)

158.18

0 (32)

95.10

10 (50)

58.80

20 (68)

37.32

30(86)

24.26

40(104)

16.13

50(122)

10.95

4.

If the measured resistance is not within specification, substitute with a known-good ambient temperature sensor and check for proper operation.

5.

Replace the ambient temperature sensor if it is proved that there is a problem with it.

Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Remove the engine room under cover front panel (A).

3.

Disconnect the connector and then remove the ambient temperature sensor (A).

4.

Install in the reverse order of removal.