If the HO2S signal voltage is fixed at lean status, then feedback control is no longer possible, the PCM/ECM sets DTC P2195.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Characteristic line strong shift | 1. Poor connection or damaged harness 2. Front HO2S |
Enable Conditions |
•
Wide range sensor pump current valid
•
Downstream O2 sensor operative readiness
•
Active test not activated
•
ngine speed > 600rpm
•
Mass air flow < 83g/sec(300kg/h)
•
572 F(300℃) < Exhaust gas temperature < 1472 F (800℃) | |
Threshold Value |
•
Plausibility between upstream and downstream
•
Upstream lean & downstream rich & lambda controller limit or upstream rich & downstrean lean & lambda controller limit | |
Diagnostic Time |
•
Less than 1300 sec. | |
Mil On Condition |
•
2 Driving Cycles |