System Inspection
■ Check Ambient Air Temperature Sensor Signal
1.

Connect GDS to DLC(Data Link Cable).

2.

Select "Air Conditioner System" and Check "Current Data" regarding ambient temperature sensor with GDS.

■ Inspection Ambient Air Temperature Sensor
3.

IG Key "OFF".

4.

Disconnect AATS connector.

5.

Measure resistance between signal and GND terminal of the AATS. (Component Side)

Specification :

Temperature

Resistance(kΩ)

Temperature

Resistance(kΩ)

-20 °C(-4 °F)

18.76~21.37

40 °C(104 °F)

1.504~1.616

0 °C(32 °F)

7.26~7.954

60 °C(140 °F)

0.757~0.835

20 °C(68 °F)

3.183~3.372

80 °C(176 °F)

0.425~0.452

25 °C(77 °F)

2.633~2.768

100 °C(212 °F)

0.220~0.255

■ Confirm Part Inspection
6.

Does the AATS work properly? (Check variation)

▶ Go to "Verification of Vehicle Repair" procedure.

▶ Substitute with a known-good AATS and check for proper operation. If the problem is corrected, replace AATS and then go to "Verification of Vehicle Repair" procedure.